<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: Resistance &#038; Reactance Grounding	</title>
	<atom:link href="https://circuitglobe.com/resistance-and-reactance-grounding.html/feed" rel="self" type="application/rss+xml" />
	<link>https://circuitglobe.com/resistance-and-reactance-grounding.html</link>
	<description>All about Electrical and Electronics</description>
	<lastBuildDate>Fri, 20 Nov 2020 12:53:27 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.2.2</generator>
	<item>
		<title>
		By: Pankaj Kumar		</title>
		<link>https://circuitglobe.com/resistance-and-reactance-grounding.html#comment-6346</link>

		<dc:creator><![CDATA[Pankaj Kumar]]></dc:creator>
		<pubDate>Fri, 20 Nov 2020 12:53:27 +0000</pubDate>
		<guid isPermaLink="false">https://circuitglobe.com/?p=4934#comment-6346</guid>

					<description><![CDATA[Very good explanation]]></description>
			<content:encoded><![CDATA[<p>Very good explanation</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: concobo norbert		</title>
		<link>https://circuitglobe.com/resistance-and-reactance-grounding.html#comment-806</link>

		<dc:creator><![CDATA[concobo norbert]]></dc:creator>
		<pubDate>Tue, 23 Jan 2018 09:32:20 +0000</pubDate>
		<guid isPermaLink="false">https://circuitglobe.com/?p=4934#comment-806</guid>

					<description><![CDATA[I ask you the quotation for a reactance of setting of neutral to the ground according to the following characteristics:
Neutral grounding inductance (reactance) 34.5 kV Quantity 1 
Installation 					outdoor 
Ambient temperature 				° C 45 
Cooling type 					AN 
Line frequency 					Hz 50 
Rated voltage 					kV 34.5 
Reactance 					Ω 6 and 7 or 30]]></description>
			<content:encoded><![CDATA[<p>I ask you the quotation for a reactance of setting of neutral to the ground according to the following characteristics:<br />
Neutral grounding inductance (reactance) 34.5 kV Quantity 1<br />
Installation 					outdoor<br />
Ambient temperature 				° C 45<br />
Cooling type 					AN<br />
Line frequency 					Hz 50<br />
Rated voltage 					kV 34.5<br />
Reactance 					Ω 6 and 7 or 30</p>